Schneider ATS48D62Y Soft Starter
Schneider ATS48D62Y
1. Core Overview
Schneider ATS48D62Y belongs to the ATS48 series of Soft Starters, which is mainly used to control the start-up, shutdown and commutation of three-phase AC motors. By adjusting the motor starting voltage, it smoothly increases the motor current, prevents the motor from generating inrush current during start-up, and protects the motor from overload and voltage surge damage.
_______________________________________________________________________________________________________
Schneider ATS48D62Y belongs to the ATS48 series of Soft Starters, which is mainly used to control the start-up, shutdown and commutation of three-phase AC motors. By adjusting the motor starting voltage, it smoothly increases the motor current, prevents the motor from generating inrush current during start-up, and protects the motor from overload and voltage surge damage.
_______________________________________________________________________________________________________
2. Key Technical Parameters
Parameter
Specific Value
Product Model
ATS48D62Y
Rated Current
22A / 62A
Voltage Range
208…690V Three-phase AC
Control Method
TEVSD48B Series Control
Motor Power Range
Suitable for motors of 3 kW – 75 kW
_______________________________________________________________________________________________________
| Parameter | Specific Value |
|---|---|
| Product Model | ATS48D62Y |
| Rated Current | 22A / 62A |
| Voltage Range | 208…690V Three-phase AC |
| Control Method | TEVSD48B Series Control |
| Motor Power Range | Suitable for motors of 3 kW – 75 kW |
_______________________________________________________________________________________________________
3. Core Product Features
- Inrush Current Suppression: During start-up, the motor starting current can be controlled within 1.5-3 times the rated current, preventing impact on the power grid and mechanical structure.
- Overload and Phase Failure Protection: Built-in multiple protection functions such as overload, overcurrent, overvoltage, undervoltage, phase failure, and phase failure start-up to ensure safe operation of the motor.
- Low Energy Consumption: Unlike frequency converters, soft starters do not consume additional power in normal operation and have extremely high efficiency.
- Compact Structure: Adopting modular design, it is small in size and light in weight, easy to install and maintain.
_______________________________________________________________________________________________________
- Inrush Current Suppression: During start-up, the motor starting current can be controlled within 1.5-3 times the rated current, preventing impact on the power grid and mechanical structure.
- Overload and Phase Failure Protection: Built-in multiple protection functions such as overload, overcurrent, overvoltage, undervoltage, phase failure, and phase failure start-up to ensure safe operation of the motor.
- Low Energy Consumption: Unlike frequency converters, soft starters do not consume additional power in normal operation and have extremely high efficiency.
- Compact Structure: Adopting modular design, it is small in size and light in weight, easy to install and maintain.
_______________________________________________________________________________________________________
4. Structure and Composition
- Main Circuit: Including main contact group, three-phase motor starting circuit and overload protection components (fuse or thermal relay).
- Control Circuit: Responsible for signal reception and processing, and executing external control commands (such as on, stop, commutation).
- Interface Board: Used to connect external control signals (such as PLC signals, on-site button signals) and motor feedback signals.
- Shell: Usually metal or plastic shell with protection level, dust-proof and waterproof.
_______________________________________________________________________________________________________
- Main Circuit: Including main contact group, three-phase motor starting circuit and overload protection components (fuse or thermal relay).
- Control Circuit: Responsible for signal reception and processing, and executing external control commands (such as on, stop, commutation).
- Interface Board: Used to connect external control signals (such as PLC signals, on-site button signals) and motor feedback signals.
- Shell: Usually metal or plastic shell with protection level, dust-proof and waterproof.
_______________________________________________________________________________________________________
5. Typical Application Fields
- Water Pump System: Prevents water pump bearings from being damaged by impact during start-up.
- Compressor: Protects the compressor from current impact during high-load start-up.
- Fans and Conveyors: Smooth start-up to prevent transmission chains or belts from breaking due to impact.
- Other Low-Voltage Motor Drives: Such as concrete mixers, elevators, etc.
_______________________________________________________________________________________________________
- Water Pump System: Prevents water pump bearings from being damaged by impact during start-up.
- Compressor: Protects the compressor from current impact during high-load start-up.
- Fans and Conveyors: Smooth start-up to prevent transmission chains or belts from breaking due to impact.
- Other Low-Voltage Motor Drives: Such as concrete mixers, elevators, etc.
_______________________________________________________________________________________________________
6. Installation and Maintenance Points
Installation Recommendations
- Wiring: Connect according to the standard wiring diagram of the ATS48 series to ensure that the motor leads correspond to the phase sequence of the soft starter.
- Heat Dissipation: Although the power consumption of ATS48D62Y is low, it still needs to be installed in a well-ventilated environment to avoid overheating.
- Position: Install on a horizontal surface, avoiding direct placement in a humid or corrosive environment.
- Wiring: Connect according to the standard wiring diagram of the ATS48 series to ensure that the motor leads correspond to the phase sequence of the soft starter.
- Heat Dissipation: Although the power consumption of ATS48D62Y is low, it still needs to be installed in a well-ventilated environment to avoid overheating.
- Position: Install on a horizontal surface, avoiding direct placement in a humid or corrosive environment.
Maintenance
- Regular Inspection: Check the tightness of terminal bolts every six months to ensure no looseness.
- Component Replacement: After the soft starter stops service, if it needs to be used continuously, replace the aging-prone components such as the internal overload relay to ensure its working reliability.
- Software Update: If the equipment is still under warranty, regularly check whether Schneider official has released firmware updates to solve potential compatibility issues.
- Regular Inspection: Check the tightness of terminal bolts every six months to ensure no looseness.
- Component Replacement: After the soft starter stops service, if it needs to be used continuously, replace the aging-prone components such as the internal overload relay to ensure its working reliability.
- Software Update: If the equipment is still under warranty, regularly check whether Schneider official has released firmware updates to solve potential compatibility issues.
------------------------------------------
------------------------------------------
Many products have not been listed yet. Please contact us for more products
📧 sales5@xrjdcs.com | 📞 +86 18250705533(WhatsApp)丨Sales Manager: Jinny
Main brand
ABB 丨 GE 丨Allen Bradley 丨 Honeywell 丨 Emerson 丨 Bently Nevada 丨 Westinghouse
Triconex 丨Foxboro 丨 ICS Triplex 丨 Hima 丨 Schneider 丨 Yokogawa 丨 Woodward & more

About Us & Our Core Strengths
As a professional supplier specializing in large-scale control systems and imported module spare parts, our company has been dedicated to delivering high-quality, tailored automation solutions for years. We cover a comprehensive range of products, from renowned brands like ABB, FOXBORO and TOSHIBA to a full selection of imported module spare parts, offering customers a seamless one-stop service experience. Guided by our core philosophy of "Delivering Value to Every Customer", we constantly expand our business horizons and have built a solid reputation among clients with our reliability and professionalism.
Our Core Business & Unique Advantages
- Spare Parts Provision: Boasting an extensive inventory of spare parts, we can quickly meet customer demands and supply authentic products from top brands including ABB, FOXBORO and TOSHIBA, ensuring quality and availability.
- Custom System Integration: Our professional engineering team, with years of practical experience in system integration, is capable of designing and implementing personalized automation system solutions that perfectly match customers' specific requirements.
- Comprehensive Technical Support: We offer all-round technical services, such as system debugging, fault troubleshooting, and regular maintenance, to guarantee the smooth and stable operation of customers' production lines.
- Fast Response & Delivery: Equipped with a well-established logistics network, we ensure prompt delivery of spare parts, minimizing customers' production downtime and reducing potential losses.
- Competitive Pricing: Through direct cooperation with original manufacturers and optimized supply chain management, we are able to offer customers highly competitive prices without compromising on product quality.
description2