PROSOFT PLX31-MBTCP-SI Power Module
PROSOFT PLX31-MBTCP-SI
The PROSOFT PLX31-MBTCP-SI is an industrial-grade communication gateway module launched by ProSoft Technology. Its core function is to convert Modbus TCP/IP protocol to Siemens Industrial Ethernet protocol, enabling high-speed, bidirectional data communication between these two mainstream industrial networks.
1. Overview
Full Name: Modbus TCP/IP to Siemens Industrial Ethernet Gateway
Function Positioning: Designed for high-speed bidirectional data transmission between controllers or devices supporting Modbus TCP/IP (such as Siemens S7-1200, S7-1500) and Siemens S7-400, S7-300, S7-200, S7-1200, S7-1500 PACs.
Core Features: Equipped with data prioritization function, which can simplify the integration process, shorten debugging time, and optimize communication performance.
Full Name: Modbus TCP/IP to Siemens Industrial Ethernet Gateway
Function Positioning: Designed for high-speed bidirectional data transmission between controllers or devices supporting Modbus TCP/IP (such as Siemens S7-1200, S7-1500) and Siemens S7-400, S7-300, S7-200, S7-1200, S7-1500 PACs.
Core Features: Equipped with data prioritization function, which can simplify the integration process, shorten debugging time, and optimize communication performance.
2. Key Specifications
Parameter
Specification/Description
Power Supply
24 VDC (nominal voltage), allowable range 10 to 36 VDC
Power Consumption
300 mA nominal, 610 mA maximum
Operating Temperature
-25°C to 70°C (-13°F to 158°F)
Storage Temperature
-40°C to 80°C (-40°F to 176°F)
Environmental Adaptability
Shock-resistant, vibration-resistant, moisture-proof (relative humidity 5% to 95% RH, non-condensing)
Physical Dimensions
5.38 x 1.99 x 4.38 inches
Interface
10/100Mbit Ethernet port
| Parameter | Specification/Description |
|---|---|
| Power Supply | 24 VDC (nominal voltage), allowable range 10 to 36 VDC |
| Power Consumption | 300 mA nominal, 610 mA maximum |
| Operating Temperature | -25°C to 70°C (-13°F to 158°F) |
| Storage Temperature | -40°C to 80°C (-40°F to 176°F) |
| Environmental Adaptability | Shock-resistant, vibration-resistant, moisture-proof (relative humidity 5% to 95% RH, non-condensing) |
| Physical Dimensions | 5.38 x 1.99 x 4.38 inches |
| Interface | 10/100Mbit Ethernet port |
3. Product Features
Multi-function Support: Supports multiple Modbus TCP/IP function codes (such as Read Coil Status, Read Holding Registers, Write Single Coil, Write Single Holding Register, etc.), and allows configuration of up to 10 clients and 5 servers.
Highly Configurable: Supports up to 160 fully configurable client commands, each of which can be enabled or disabled independently, and supports write-on-data-change function.
Safety and Certifications: Has passed multiple international safety certifications, including ATEX, CB, KC, UL, RoHS/CE, EAC and REACH, etc.
Multi-function Support: Supports multiple Modbus TCP/IP function codes (such as Read Coil Status, Read Holding Registers, Write Single Coil, Write Single Holding Register, etc.), and allows configuration of up to 10 clients and 5 servers.
Highly Configurable: Supports up to 160 fully configurable client commands, each of which can be enabled or disabled independently, and supports write-on-data-change function.
Safety and Certifications: Has passed multiple international safety certifications, including ATEX, CB, KC, UL, RoHS/CE, EAC and REACH, etc.
4. Structure and Composition
Industrial-grade Encapsulation: The module is ruggedly designed to operate in harsh industrial environments. The specific internal composition usually includes a power management module, an Ethernet interface module, a processor module, and an input/output interface module, but detailed internal layout information is rarely available in public materials.
5. Application Areas
Industrial Automation: Widely used in scenarios requiring data interaction between Modbus TCP/IP and Siemens PLCs (S7 series), such as sensor networks, remote monitoring systems, process control systems, etc.
Cross-platform Integration: In hybrid automation systems, it serves as a bridge to connect hardware devices from different manufacturers, ensuring data consistency and real-time performance.
Industrial Automation: Widely used in scenarios requiring data interaction between Modbus TCP/IP and Siemens PLCs (S7 series), such as sensor networks, remote monitoring systems, process control systems, etc.
Cross-platform Integration: In hybrid automation systems, it serves as a bridge to connect hardware devices from different manufacturers, ensuring data consistency and real-time performance.
6. Installation and Maintenance
Installation Method: Usually adopts DIN rail mounting or panel mounting, depending on the specific design of the industrial control chassis or distribution cabinet.
Maintenance Recommendations:
- Environmental Inspection: Ensure the installation environment meets its operating temperature and humidity requirements to avoid equipment failure caused by overheating or humidity.
- Power Supply Monitoring: Regularly check whether the power supply voltage is within the range of 10VDC to 36VDC to prevent voltage fluctuations from affecting communication stability.
- Firmware Update: Regularly check the ProSoft official website for new firmware versions to obtain the latest function optimizations and security patches.
Installation Method: Usually adopts DIN rail mounting or panel mounting, depending on the specific design of the industrial control chassis or distribution cabinet.
Maintenance Recommendations:
- Environmental Inspection: Ensure the installation environment meets its operating temperature and humidity requirements to avoid equipment failure caused by overheating or humidity.
- Power Supply Monitoring: Regularly check whether the power supply voltage is within the range of 10VDC to 36VDC to prevent voltage fluctuations from affecting communication stability.
- Firmware Update: Regularly check the ProSoft official website for new firmware versions to obtain the latest function optimizations and security patches.
------------------------------------------
Many products have not been listed yet. Please contact us for more products
📧 sales5@xrjdcs.com | 📞 +86 18250705533(WhatsApp)丨Sales Manager: Jinny
Main brand
ABB 丨 GE 丨Allen Bradley 丨 Honeywell 丨 Emerson 丨 Bently Nevada 丨 Westinghouse
Triconex 丨Foxboro 丨 ICS Triplex 丨 Hima 丨 Schneider 丨 Yokogawa 丨 Woodward & more

Product Advantages, Payment & Shipping Terms
Core Advantages
- Ample in-stock inventory for swift order fulfillment
- Competitive pricing tiers and timely quotation responses
- Comprehensive product specifications and high-resolution images provided
- Dedicated professional support and technical consultation services
- 12-month warranty coverage for all qualified products
- Rigorous pre-delivery inspection and performance testing
Accepted Payment Methods
Telegraphic Transfer (T/T) / PayPal / Western Union / MoneyGram
Shipping Options
We offer flexible shipping solutions via DHL, FedEx, TNT, UPS, and EMS. You are free to select the shipping carrier that best fits your timeline and budget.
Our Product Guarantees
- Guarantee 1: All products are 100% brand-new and original imported
- Guarantee 2: Secure and punctual delivery as scheduled
- Guarantee 3: High-quality after-sales service and technical assistance
Favorable pricing with abundant stock ready for immediate shipment.
Order Processing Flow
- Step 1: Customer specifies and confirms the exact product model(s) required
- Step 2: Our team verifies the model availability and delivery timeframe, then issues a detailed official quotation
- Step 3: Customer reviews the quotation, confirms the model accuracy, and proceeds to place the order
- Step 4: The assigned account manager prepares a formal sales contract based on the confirmed model(s) and quantity
- Step 5: Customer reviews the contract, signs and returns it (with company seal if applicable), then completes payment in accordance with the contract terms
- Step 6: Upon payment confirmation by our finance department, the sales team arranges shipment promptly and informs the customer of the tracking number for order monitoring
description2