PROSOFT MVI94-MCM Communication Interface Module
PROSOFT MVI94-MCM
The ProSoft MVI94‑MCM is an industrial communication interface module manufactured by ProSoft Technologies (USA/Japan). It is specifically designed for Rockwell Automation’s Flex I/O platform, enabling seamless data exchange between Flex I/O systems and Modbus networks.
1. Overview
Core Function: Facilitates communication between Rockwell Flex I/O (1756 Flex I/O) and Modbus master/slave networks.Processor: Powered by a Texas Instruments TMS320C6000 series DSP, delivering high precision and exceptional stability.
Application: Widely used in large‑scale industrial automation sectors such as oil and gas, power generation, petrochemicals, and metallurgy.
Processor: Powered by a Texas Instruments TMS320C6000 series DSP, delivering high precision and exceptional stability.
Application: Widely used in large‑scale industrial automation sectors such as oil and gas, power generation, petrochemicals, and metallurgy.
2. Specifications
Power Supply: 24V DC ±20%Current Draw: 20 mA (backplane)
Operating Temperature: 0°C to 55°C (industrial grade)
Storage Temperature: -40°C to 85°C
Dimensions: Single‑slot 1794 form factor (compatible with 1756 Flex I/O backplane)
Communication Interface: 1756 Flex I/O backplane compatible (RS‑485)
Protocols: Modbus RTU (serial), Modbus TCP (Ethernet)
Data Mapping: Supports up to 10,000 + 1,000 registers (depending on configuration)
Current Draw: 20 mA (backplane)
Operating Temperature: 0°C to 55°C (industrial grade)
Storage Temperature: -40°C to 85°C
Dimensions: Single‑slot 1794 form factor (compatible with 1756 Flex I/O backplane)
Communication Interface: 1756 Flex I/O backplane compatible (RS‑485)
Protocols: Modbus RTU (serial), Modbus TCP (Ethernet)
Data Mapping: Supports up to 10,000 + 1,000 registers (depending on configuration)
3. Key Features
High Compatibility: Communicates with a wide range of Modbus devices, including PLCs, VFDs, and sensors.Modular Design: Single‑slot form factor for easy installation and space‑saving integration with Flex I/O backplanes.
Reliability: Industrial‑grade DSP chip provides strong anti‑interference capabilities and long operational life.
Modular Design: Single‑slot form factor for easy installation and space‑saving integration with Flex I/O backplanes.
Reliability: Industrial‑grade DSP chip provides strong anti‑interference capabilities and long operational life.
4. Structure and Components
Slot Module: Single‑slot 1794 module that plugs directly into the Flex I/O backplane.Communication Circuitry: Integrated RS‑485 transceiver for serial communication at the physical layer.
Register Mapping: Large set of digital I/O registers accessible directly from the PLC for reading and writing.
Communication Circuitry: Integrated RS‑485 transceiver for serial communication at the physical layer.
Register Mapping: Large set of digital I/O registers accessible directly from the PLC for reading and writing.
5. Application Areas
Industrial Automation: Connects PLCs with Modbus devices for data acquisition and control.Process Control: Used in distributed control systems (DCS) in oil, gas, and power industries.
Equipment Integration: Interfaces with smart sensors, variable frequency drives, and intelligent instrumentation.
Process Control: Used in distributed control systems (DCS) in oil, gas, and power industries.
Equipment Integration: Interfaces with smart sensors, variable frequency drives, and intelligent instrumentation.
6. Installation and Maintenance
Installation: Power off the PLC, then insert the MVI94‑MCM into an available slot on the Flex I/O backplane.Wiring: Connect to an RS‑485 network or Ethernet (depending on the specific model), ensuring proper termination.
Configuration: Set up module parameters and register mapping using Rockwell’s RSLogix 5000 software.
Maintenance: Hot‑swappable design allows for easy replacement in case of module failure.
Wiring: Connect to an RS‑485 network or Ethernet (depending on the specific model), ensuring proper termination.
Configuration: Set up module parameters and register mapping using Rockwell’s RSLogix 5000 software.
Maintenance: Hot‑swappable design allows for easy replacement in case of module failure.
------------------------------------------
Many products have not been listed yet. Please contact us for more products
📧 sales5@xrjdcs.com | 📞 +86 18250705533(WhatsApp)丨Sales Manager: Jinny
Main brand
ABB 丨 GE 丨Allen Bradley 丨 Honeywell 丨 Emerson 丨 Bently Nevada 丨 Westinghouse
Triconex 丨Foxboro 丨 ICS Triplex 丨 Hima 丨 Schneider 丨 Yokogawa 丨 Woodward & more

Product Advantages, Payment & Shipping Terms
Core Advantages
- Ample in-stock inventory for swift order fulfillment
- Competitive pricing tiers and timely quotation responses
- Comprehensive product specifications and high-resolution images provided
- Dedicated professional support and technical consultation services
- 12-month warranty coverage for all qualified products
- Rigorous pre-delivery inspection and performance testing
Accepted Payment Methods
Shipping Options
Our Product Guarantees
- Guarantee 1: All products are 100% brand-new and original imported
- Guarantee 2: Secure and punctual delivery as scheduled
- Guarantee 3: High-quality after-sales service and technical assistance
Order Processing Flow
- Step 1: Customer specifies and confirms the exact product model(s) required
- Step 2: Our team verifies the model availability and delivery timeframe, then issues a detailed official quotation
- Step 3: Customer reviews the quotation, confirms the model accuracy, and proceeds to place the order
- Step 4: The assigned account manager prepares a formal sales contract based on the confirmed model(s) and quantity
- Step 5: Customer reviews the contract, signs and returns it (with company seal if applicable), then completes payment in accordance with the contract terms
- Step 6: Upon payment confirmation by our finance department, the sales team arranges shipment promptly and informs the customer of the tracking number for order monitoring