Honeywell C7076A1007 Flame Detector
Honeywell C7076A1007
1. Product Overview
Honeywell C7076A1007 is an ultraviolet (UV) flame detector specifically designed for industrial combustion systems. It features adjustable sensitivity, a wide temperature/voltage operating range, and a self-check function. The detector can reliably capture UV radiation from flames of natural gas, oil, pulverized coal, etc., enabling safe flame monitoring.
2. Key Technical Specifications
Parameter
Specification
Model
C7076A1007 / C7076A1007‑U
Electrical Connection
Terminal Block
Mounting Method
1-inch NPT Flange
Protection Class
NEMA 4 (Dust and Water Resistant)
Ambient Temperature Range
-40 °F ~ +160 °F (-40 °C ~ +71 °C)
Rated Voltage
120 VAC (100 VAC/220-240 VAC Optional)
Frequency
50 Hz / 60 Hz (Depending on Model)
Sensitivity Setting
Two Adjustable Levels, Single-level Dynamic Range 400:1
Output Signal
High Level (Suitable for Long-distance Transmission)
Operating Temperature
-40 °C ~ +71 °C
Power Supply Voltage
120 VAC (or Corresponding Voltage Model)
| Parameter | Specification |
|---|---|
| Model | C7076A1007 / C7076A1007‑U |
| Electrical Connection | Terminal Block |
| Mounting Method | 1-inch NPT Flange |
| Protection Class | NEMA 4 (Dust and Water Resistant) |
| Ambient Temperature Range | -40 °F ~ +160 °F (-40 °C ~ +71 °C) |
| Rated Voltage | 120 VAC (100 VAC/220-240 VAC Optional) |
| Frequency | 50 Hz / 60 Hz (Depending on Model) |
| Sensitivity Setting | Two Adjustable Levels, Single-level Dynamic Range 400:1 |
| Output Signal | High Level (Suitable for Long-distance Transmission) |
| Operating Temperature | -40 °C ~ +71 °C |
| Power Supply Voltage | 120 VAC (or Corresponding Voltage Model) |
3. Product Features
- Adjustable Sensitivity: Two adjustable levels to meet the sensitivity requirements of different burners.
- Wide Temperature/Voltage Adaptability: Maintains stable performance even in extreme environments.
- Self-check Function: Built-in UV amplifier (R7886) enables closed-loop self-check to ensure the integrity of the detector and amplifier.
- Long-distance Output: High-level output requires no special wiring, making it suitable for on-site long-distance monitoring.
- Solid-state Circuitry: No mechanical wear, ensuring long service life and high reliability.
- NEMA 4 Protection Class: Dust and water resistant, applicable to harsh industrial sites.
4. Structure and Composition
- Housing: Metal frame with a 1-inch NPT interface.
- UV Detection Unit: Solid-state UV sensor responsible for capturing UV radiation from flames.
- Amplifier Module: R7886 dynamic self-check UV amplifier, forming a closed-loop self-check circuit.
- Electrical Terminal Block: Terminal block wiring for quick on-site wiring.
- Output Signal Interface: High-level output terminal supporting long-distance transmission.
- Adjustment Screw: Mechanical adjustment device for sensitivity adjustment.
5. Typical Application Fields
- Industrial combustion systems (boilers, furnaces, heat treatment equipment)
- Flame monitoring in natural gas/oil refining processes
- On-site safety protection for pulverized coal combustion and metal smelting
- Flame detection in combined heat and power (CHP) and waste gas treatment systems
- Flame safety interlock in petrochemical and chemical production lines
6. Installation Key Points
- Installation Location: Choose a position with an unobstructed line of sight, close to the combustion area, and easy for maintenance.
- Interface Connection: Use a 1-inch NPT flange to correctly connect with pipelines and power supply terminal blocks.
- Protection Measures: Ensure the housing is intact to prevent dust and moisture from entering.
- Power Supply Check: Confirm that the power supply voltage matches the model to avoid overvoltage or undervoltage.
- Commissioning: After the first power-on, perform sensitivity adjustment and self-check function verification.
7. Maintenance
- Regular Cleaning: Keep the detection window free of dust and oil stains to prevent signal attenuation.
- Self-check Inspection: Use the built-in self-check function to regularly confirm that the amplifier and detector work normally.
- Electrical Inspection: Check that terminal connections are tight, without looseness or corrosion.
- Calibration: If necessary, re-adjust the sensitivity according to on-site flame characteristics.
- Replacement Cycle: Depending on the operating environment, it is recommended to replace the detection unit every 3-5 years to ensure no sensitivity degradation.
------------------------------------------
Many products have not been listed yet. Please contact us for more products
📧 sales5@xrjdcs.com | 📞 +86 18250705533(WhatsApp)丨Sales Manager: Jinny
Main brand
ABB 丨 GE 丨Allen Bradley 丨 Honeywell 丨 Emerson 丨 Bently Nevada 丨 Westinghouse
Triconex 丨Foxboro 丨 ICS Triplex 丨 Hima 丨 Schneider 丨 Yokogawa 丨 Woodward & more

Our Company Profile
description2