Honeywell 2002-400-090-126-385-20-100000-1-0-00 Actuator
Honeywell 2002-400-090-126-385-20-100000-1-0-00
Overview
Honeywell 2002-400-090-126-385-20-100000-1-0-00 is an electric rotary actuator specifically designed for three-quarter turn (90°) valves such as butterfly valves and damper valves. It adopts a standard on/off control method, and is equipped with manual reset, visual position indication and IP67 protection rating. It is suitable for scenarios including HVAC, industrial automation and process control.
Main Specifications
- Torque: 400 Nm (rated)
- Rotation angle: 90° (three-quarter turn)
- Power supply: 230 VAC (24 VDC optional)
- Control method: On-Off signal, with dry contact output
- Manual reset: Non-clutch manual reset, allowing direct manual adjustment of valve position after power failure
- Indication device: Mechanical visual position indicator, facilitating quick on-site confirmation of valve status
- Protection rating: IP67, dust-proof and waterproof, suitable for harsh environments
- Additional functions: Condensation prevention heater, two auxiliary limit switches (standard configuration)
Product Features
- High reliability: Adopts irreversible helical gear transmission to prevent accidental rotation; IP67 enclosure ensures protection performance for long-term operation.
- Easy installation: Standard flange interface (DN 50-DN 500, PN16), enabling direct replacement of existing valve actuators.
- Convenient maintenance: No additional tools are required for manual reset, and the mechanical position indicator eliminates the need for maintenance of additional sensors.
- Versatility: Equipped with dry contact output and two auxiliary limit switches, facilitating linkage with upper-level systems.
- Energy efficiency: Heating function is only provided when needed, reducing energy consumption.
Structure and Composition
- Motor: Driven by a low-voltage motor, providing a rated torque of 400 Nm.
- Gearbox: Irreversible helical gear, ensuring the valve maintains its position after power failure.
- Enclosure: Metal protective shell, complying with IP67 standard.
- Manual reset mechanism: Non-clutch handle, allowing direct manual adjustment after power failure.
- Position indicator: Mechanical pointer or window-type indicator, showing the on/off status of the valve.
- Auxiliary switch: Two limit switches (optional), providing additional safety protection.
- Condensation prevention heater: Built-in electric heating element, preventing the valve from freezing in low-temperature environments.
Typical Application Fields
- HVAC: Controls large-diameter butterfly valves and damper valves to realize the on/off of cold and hot water, and steam systems.
- Industrial process control: Used for valve automation in industries such as chemical engineering, petroleum and energy.
- Building automation: Ventilation, air conditioning and heating valves in building automation systems.
- Water treatment and wastewater treatment: Adjusts valve flow to ensure the safe operation of the system.
Installation and Maintenance Points
- Pre-installation inspection: Confirm that the valve flange size and pressure rating (PN16) match the actuator flange.
- Electrical wiring: Wire according to the power supply voltage (230 VAC or 24 VDC), and ensure the dry contact corresponds to the control cabinet signal.
- Manual reset test: In the power-off state, use the manual reset handle to check whether the valve can be adjusted smoothly.
- Position indication calibration: Calibrate the mechanical indicator after installation to ensure the indication is consistent with the actual valve position.
- Regular inspection: Check the lubrication of the helical gear, the function of the heater and the working status of the limit switch every 6-12 months.
- Protection and maintenance: Keep the enclosure clean to prevent dust and corrosive substances from entering; if used in extreme environments, it is recommended to install an additional protective cover.
------------------------------------------
Many products have not been listed yet. Please contact us for more products
📧 sales5@xrjdcs.com | 📞 +86 18250705533(WhatsApp)丨Sales Manager: Jinny
Main brand
ABB 丨 GE 丨Allen Bradley 丨 Honeywell 丨 Emerson 丨 Bently Nevada 丨 Westinghouse
Triconex 丨Foxboro 丨 ICS Triplex 丨 Hima 丨 Schneider 丨 Yokogawa 丨 Woodward & more

Our Company Profile
description2