HIMA KFD2-VR4-Ex1.26 voltage repeater
HIMA KFD2-VR4-Ex1.26
Overview
The HIMA KFD2-VR4-Ex1.26 is a voltage repeater designed for isolating and converting voltage signals, suitable for industrial sites and hazardous areas. It supports signal transmission from various sensors (such as vibration sensors and acceleration sensors) and complies with the SIL 2 safety level standard.
The HIMA KFD2-VR4-Ex1.26 is a voltage repeater designed for isolating and converting voltage signals, suitable for industrial sites and hazardous areas. It supports signal transmission from various sensors (such as vibration sensors and acceleration sensors) and complies with the SIL 2 safety level standard.
Parameters
- Input/Output Voltage Range: 0 V to -20 V (for both input and output).
- Isolation Voltage: 24 V DC (power rail).
- Isolation Level: SIL 2 (compliant with IEC/EN 61508 standard).
- Power Supply Voltage: 19-30 V DC (rated).
- Power Consumption: ≤1.6 W (maximum).
- Input Resistance: 10 kΩ.
- Output Resistance: 24 Ω (typical value), maximum 27 Ω.
- Protection Level: IP20.
- Operating Temperature: -20 to 60 °C.
- Input/Output Voltage Range: 0 V to -20 V (for both input and output).
- Isolation Voltage: 24 V DC (power rail).
- Isolation Level: SIL 2 (compliant with IEC/EN 61508 standard).
- Power Supply Voltage: 19-30 V DC (rated).
- Power Consumption: ≤1.6 W (maximum).
- Input Resistance: 10 kΩ.
- Output Resistance: 24 Ω (typical value), maximum 27 Ω.
- Protection Level: IP20.
- Operating Temperature: -20 to 60 °C.
Product Features
- High Isolation Performance: Complies with the SIL 2 standard, suitable for intrinsic safety applications.
- Multi-Sensor Compatibility: Supports 2-wire and 3-wire sensors (such as vibration sensors and acceleration sensors).
- Multi-Language Support: Provides multiple language versions and product documentation.
- Safety Design: Intrinsically safe design, applicable for hazardous areas.
- High Isolation Performance: Complies with the SIL 2 standard, suitable for intrinsic safety applications.
- Multi-Sensor Compatibility: Supports 2-wire and 3-wire sensors (such as vibration sensors and acceleration sensors).
- Multi-Language Support: Provides multiple language versions and product documentation.
- Safety Design: Intrinsically safe design, applicable for hazardous areas.
Structure and Composition
- Installation Method: DIN rail mounting, compatible with DIN rails and power rails (e.g., UPR-03).
- Mechanical Specifications: Dimensions 20×119×115 mm, weight approximately 125 g.
- Terminal Connection: Removable terminals, LED indicator light (for power status).
- Protection Level: IP20 protection.
- Installation Method: DIN rail mounting, compatible with DIN rails and power rails (e.g., UPR-03).
- Mechanical Specifications: Dimensions 20×119×115 mm, weight approximately 125 g.
- Terminal Connection: Removable terminals, LED indicator light (for power status).
- Protection Level: IP20 protection.
Application Fields
- Industrial Automation: Used for signal transmission and isolation in industrial sites.
- Hazardous Areas: Suitable for sensor signal transmission (such as vibration sensors and acceleration sensors) in hazardous areas.
- Sensor Integration: Supports integration with systems like DCS and PLC.
- Industrial Automation: Used for signal transmission and isolation in industrial sites.
- Hazardous Areas: Suitable for sensor signal transmission (such as vibration sensors and acceleration sensors) in hazardous areas.
- Sensor Integration: Supports integration with systems like DCS and PLC.
Installation and Maintenance
- Installation: Mount via DIN rail, following the installation guide and electrical safety standards.
- Maintenance: Conduct regular cleaning, inspect connections and interfaces, and ensure proper heat dissipation and ventilation.
- Installation: Mount via DIN rail, following the installation guide and electrical safety standards.
- Maintenance: Conduct regular cleaning, inspect connections and interfaces, and ensure proper heat dissipation and ventilation.
------------------------------------------

Many products have not been listed yet. Please contact us for more products
📧 sales5@xrjdcs.com | 📞 +86 18250705533(WhatsApp)丨Sales Manager: Jinny