ABB A260-30-22-80 AC contactor
ABB A260-30-22-80
1. Overview
The ABB A260-30-22-80 is a 3-pole AC contactor belonging to the ABB A-series AC contactor lineup, with a rated current of 260A. It is widely used in the field of motor control and protection. Adopting an air arc extinguishing medium and supporting multiple coil voltage specifications, this contactor is applicable to various types of electrical control systems.
2. Technical Parameters
Parameter Item
Specification
Rated Current
260A
Number of Poles
3 Poles
Rated Voltage
24-690V
Coil Voltage
AC24V/110V/220V/380V, etc.
Coil Frequency
50Hz/60Hz
Conventional Thermal Current
400A
Operating Temperature
-40~+70℃
Operating Altitude
≤3000m
Mechanical Life
1,000,000 times
Main Contacts
3 Normally Open (3NO)
Auxiliary Contacts
2NO+2NC (indicated by the suffix -22 of the model)
Overall Dimensions
Approx. 140mm×227mm×180.5mm
| Parameter Item | Specification |
|---|---|
| Rated Current | 260A |
| Number of Poles | 3 Poles |
| Rated Voltage | 24-690V |
| Coil Voltage | AC24V/110V/220V/380V, etc. |
| Coil Frequency | 50Hz/60Hz |
| Conventional Thermal Current | 400A |
| Operating Temperature | -40~+70℃ |
| Operating Altitude | ≤3000m |
| Mechanical Life | 1,000,000 times |
| Main Contacts | 3 Normally Open (3NO) |
| Auxiliary Contacts | 2NO+2NC (indicated by the suffix -22 of the model) |
| Overall Dimensions | Approx. 140mm×227mm×180.5mm |
3. Product Features
- Reliable contact performance and long service life
- High temperature resistance and corrosion resistance
- Compact and integrated structure
- Air-type arc extinguishing design for safe operation
- Flexible installation: supports vertical and horizontal mounting
- Compatible with DIN rail installation
- Reliable contact performance and long service life
- High temperature resistance and corrosion resistance
- Compact and integrated structure
- Air-type arc extinguishing design for safe operation
- Flexible installation: supports vertical and horizontal mounting
- Compatible with DIN rail installation
4. Structure and Composition
4.1 Core System Configuration
- Main Contact System: 3-pole normally open contacts (3NO)
- Auxiliary Contact System: 2NO+2NC auxiliary contacts
- Electromagnetic System: Consists of coil, moving iron core and static iron core
- Arc Extinguishing System: Equipped with air-type arc extinguishing device
- Main Contact System: 3-pole normally open contacts (3NO)
- Auxiliary Contact System: 2NO+2NC auxiliary contacts
- Electromagnetic System: Consists of coil, moving iron core and static iron core
- Arc Extinguishing System: Equipped with air-type arc extinguishing device
4.2 Terminal Definition
- Main Circuit Inlet: 1L1, 3L2, 5L3
- Main Circuit Outlet: 2T1, 4T2, 6T3
- Normally Open (NO) Auxiliary Contact Inlet: 13, 23, 33, 43
- Normally Open (NO) Auxiliary Contact Outlet: 14, 24, 34, 44
- Normally Closed (NC) Auxiliary Contact Inlet: 11, 21, 31, 41
- Normally Closed (NC) Auxiliary Contact Outlet: 12, 22, 32, 42
- Coil Terminals: A1, A2
- Main Circuit Inlet: 1L1, 3L2, 5L3
- Main Circuit Outlet: 2T1, 4T2, 6T3
- Normally Open (NO) Auxiliary Contact Inlet: 13, 23, 33, 43
- Normally Open (NO) Auxiliary Contact Outlet: 14, 24, 34, 44
- Normally Closed (NC) Auxiliary Contact Inlet: 11, 21, 31, 41
- Normally Closed (NC) Auxiliary Contact Outlet: 12, 22, 32, 42
- Coil Terminals: A1, A2
5. Application Fields
- Motor control and protection systems
- Power energy management equipment
- Industrial electrical control systems
- Three-phase motor load control scenarios
- Motor control and protection systems
- Power energy management equipment
- Industrial electrical control systems
- Three-phase motor load control scenarios
6. Installation and Maintenance
6.1 Installation Specifications
- Installation Direction: Vertical or horizontal installation is permitted; the inclination angle shall not exceed ±30° during vertical installation
- Installation Method: Standard DIN rail mounting
- Wiring Requirement: Wire strictly in accordance with terminal marks to ensure correct circuit connection
- Installation Direction: Vertical or horizontal installation is permitted; the inclination angle shall not exceed ±30° during vertical installation
- Installation Method: Standard DIN rail mounting
- Wiring Requirement: Wire strictly in accordance with terminal marks to ensure correct circuit connection
6.2 Environmental Requirements
Pollution Level: Level 3; Operating Temperature: -40~+70℃; Maximum Operating Altitude: ≤3000m
6.3 Maintenance Guidelines
Regularly inspect the contact working status, clean surface dust and dirt regularly, and check all wiring terminals to ensure firm connection and stable equipment operation.
------------------------------------------

Many products have not been listed yet. Please contact us for more products
📧 sales5@xrjdcs.com | 📞 +86 18250705533(WhatsApp)丨Sales Manager: Jinny
Main brand
ABB 丨 GE 丨Allen Bradley 丨 Honeywell 丨 Emerson 丨 Bently Nevada 丨 Westinghouse
Triconex 丨Foxboro 丨 ICS Triplex 丨 Hima 丨 Schneider 丨 Yokogawa 丨 Woodward & more

⇒The following are our main activities
Taken the ABB (AC800M/AC800F/AC800PEC/AC900F/excitation control)
★GE VMIVME/ VMIC series CPU mainboard
Relay protection SR469/SR369/SR489/SR750
IS200/IS215/IS220/ IS420/ DS200/DS215
/IC693/IC694/IC695/IC697/IC698
★ Invensys (3008, 3625, 3508E.3721, 3700A 4351B Safety system module)
★ Bentley (3500/42M, 3500/22M, 3500/95.3500/05)
★ Woodward 9907 series 505 governor, 8840 series controller, module
★ Foxboro (FBM230, FBM232, FCP270, H90/H92)
★ Emerson Westinghouse module 1C311/1C312, DELTAV module EPRO sensor
★ Dark Horse (F3330, F3236, F6217, F7126, F8621A)
★ Schneider Modicon 140 series CPU, communication module ELAU servo
★ Prosofte MVI46/56/69, AB, communication module
description2